Place of Origin: | China |
Brand Name: | HongCe |
Certification: | Calibration certificate(cost additional) |
Model Number: | HC-HJMN001 |
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiation |
Packaging Details: | Plywood |
Delivery Time: | 90 days |
Payment Terms: | T/T |
Supply Ability: | 1 Sets per 3 month |
Model: | HC-HJMN001 | Resolution: | 0.1 Or 0.01℃ |
---|---|---|---|
Temperature Control System: | Fully Enclosed Or Semi-enclosed Compressor | Observation Window: | Multi-layer Hollow Electroplated Film Heated Explosion-proof Glass |
Laboratory Size: | Can Be Customized According To User Needs, Common Sizes Are 1m³, 2m³, 3m³, Etc | Optional Accessories: | Emperature And Humidity Recorder, Number Of Doors, SMS Alarm, Controller Brand, Compressor Brand, Etc. |
Highlight: | Advanced Temperature Control IP Testing Equipment,Precise Temperature Control IP Testing Equipment,IEC 60068-2 IP Testing Equipment |
Walk-in high and low temperature environment simulation laboratory
Product Introduction:
The walk-in high and low temperature environment simulation laboratory is a high-performance testing equipment, which is mainly used to simulate various extreme high and low temperature environments and conduct reliability tests on products. It is widely used in electronics, electrical appliances, communications, automobiles, aerospace and other fields, providing companies with accurate and reliable test data, helping them improve product quality and competitiveness.
Test Standards:
IEC 60068-2-1: Low temperature test methods.
IEC 60068-2-2: High temperature test methods.
ISO 16750: Environmental conditions and testing for electrical and electronic equipment in road vehicles.
Product features:
Wide temperature range: It can achieve a wide range of temperature control from extremely low temperature to extremely high temperature to meet the testing needs of different products.
High precision: It adopts advanced temperature control technology to accurately control the temperature inside the laboratory and ensure the accuracy of the test results.
Good stability: It has good temperature stability and can maintain a stable temperature environment during long-term testing.
Easy to operate: It is equipped with an advanced control system, which is simple and convenient to operate. Users can easily set and adjust test parameters.
Safe and reliable: It has complete safety protection measures, such as over-temperature protection, leakage protection, etc., to ensure the safety and reliability of the test process.
Energy saving and environmental protection: It adopts efficient refrigeration and heating technology, which is energy-saving and environmentally friendly and reduces operating costs.
Product Principle:
The walk-in high and low temperature environment simulation laboratory is mainly composed of a refrigeration system, a heating system, a control system, a circulating air system, etc. The refrigeration system uses a compressor to cool the room and discharge the heat inside the laboratory to achieve cooling; the heating system transfers the heat to the inside of the laboratory through electric heating or other heating methods to achieve heating. The control system monitors the temperature inside the laboratory in real time through sensors, and automatically controls the operation of the refrigeration and heating systems according to the set temperature value to maintain a stable temperature inside the laboratory. The circulating air system circulates the air through a fan to evenly distribute the temperature inside the laboratory.
Technical parameters:
Operating temperature range | +80℃ (100℃, 120℃, 150℃) ~ -70℃ (A: 0℃, B: -20℃, C: -40℃, D: -60℃, E-70℃) |
Temperature deviation | ≤±2℃ |
Humidity deviation | +2/-3%RH |
Heating time | ≤40min |
Cooling time | 30min~180min (depending on different models) |
Material | A3 steel plate + spray coating for the outside, SUS#304 stainless steel for the inside, PU foam and insulation cotton for the insulation layer |
Power supply | AC380(1±10%)V, 50±0.5HZ, three-phase four-wire + protective ground wire |
Optional accessories | Temperature and humidity recorder, number of doors, SMS alarm, controller brand, compressor brand, etc. |
Detailed image:
FAQ:
Q1: What is the temperature control accuracy of the walk-in high and low temperature environment simulation laboratory?
A: Generally within ±0.5℃, the specific accuracy can be adjusted according to user needs.
Q2: What waterproof level tests can be performed in this laboratory?
A: Usually it can meet the waterproof level test requirements of IPX5 and IPX6.
Q3: Can the studio size of the walk-in high and low temperature environment simulation laboratory be customized?
A: Yes, the studio size can be customized according to user needs.
Q4: What are the heating rate and cooling rate of this laboratory?
A: The heating rate is generally between 1℃/min and 5℃/min, and the cooling rate is generally between 0.7℃/min and 1.5℃/min, which can be adjusted according to user needs.
Q5: What are the power requirements of the laboratory?
A: Depending on the power of the equipment, it is generally a 380V/50Hz three-phase five-wire power supply.
Contact Person: Ms. Tessa Huang
Tel: +86 18933919125